Company Details
  • Wenzhou Korlen Electric Appliances Co., Ltd.

  •  [Zhejiang,China]
  • Business Type:Distributor/Wholesaler , Manufacturer , Service , Trade Company
  • Main Markets: Africa , Americas , Asia , Caribbean , East Europe , Europe , Middle East , North Europe , Oceania , Other Markets , West Europe , Worldwide
  • Exporter:91% - 100%
  • Certs:ISO14001, ISO9001, ISO9002, CB, CE, EMC, RoHS, TUV, UL, OHSAS18001, CCC
  • Description:The Residual Current Circuit Breaker,Circuit Breaker Working,House Circuit Breakers
Wenzhou Korlen Electric Appliances Co., Ltd. The Residual Current Circuit Breaker,Circuit Breaker Working,House Circuit Breakers
Home > Products > Miniature Circuit Breaker > KNB1-63 Miniature Circuit Breaker > Residual Current Circuit Breaker For Building

Residual Current Circuit Breaker For Building

Share to:  
    Unit Price: USD 1 / Bag/Bags
    Payment Type: L/C,T/T,D/P,Paypal
    Min. Order: 1 Bag/Bags
  • Ms. Chen

Basic Info

Model No.KNL1-63(F360) Normal type

BrandKorlen

Breaking CapacityLow Voltage Circuit Breakers

OperationManual Type

SpeedNormal Type Circuit Breaker

Arc-extinguishing MediumAir

InstallationFixed

StructureMcb

Poles Number2

TypeCircuit Breaker

FunctionConventional Circuit Breaker

CertificationCe

Frame63a

Rated Working Voltage240v/415v

Rated Limiting Short-circuit Current3000a

Rated Worling Current16;20;25;32;40;50;63a

SensibilityActype

Additional Info

Packagingcarton

Productivity500000PCS/Year

TransportationOcean,Land,Air

Place of OriginWenzhou; Zhejiang; China

CertificateCE,CB

HS Code8536200000

PortNingbo,ShangHai

Payment TypeL/C,T/T,D/P,Paypal

Product Description

KNB1-63 Miniature Circuit Breaker

Provides protection against earth fault/leakage current and function of isolation
Applicable to terminal and pin/fork type busbar connection
Fire resistant plastic parts endures abnormal heating and strong impact
Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds therated sensitivity.
Independent of power supply and line voltage, and free from external interference, voltage fl uctuation.

KNL1-63 series Residual Current Circuit Breaker(without over-current protection) is suitable for the line of AC 50/60Hz, voltage 240V(2 pole)/415V(4 pole), rated current up to 63A. When there is human electricity shock or if the leakage current of the line exceeds the prescribed value, it will cut off the power rapidly to protect human safety and prevent the accident due to the current leakage. It can be used as infrequent changeover of the line in normal situation.It is applicable to industrial site, commercial site, tall building and civil house.

It complies with standard of GB16916.1 and IEC/EN61008.1.

 

Basic specification and main parameters  

Residual Current Circuit Breaker
Ac Residual Current Circuit Breaker
Miniature Residual Current Circuit Breaker
Residual Current Electrical Circuit Breaker

Frame

63A

Rated working voltage

240/415V

Rated frequency

50/60Hz

Rated working current

16.20.25.32.40.50.63A

Rated residual operating current

0.03,0.1,0.3,0.5A

Rated residual un-operating current

0.015,0.05,0.15,0.25A

Sensibility

A Type.S Type.AC Type

Maximum operating time

I△n t≤0.1s , 5I△n t≤0.04

Rated making and breaking capacity

In≤50A 500A,In=63A 630A

Limiting value of un-operating current

6In

Rated limiting short-circuit current

3000A

Pole number

2.4P

Mechanical life

10000

Electric life

4000

Operation principle 
Each phase of conductor at the circuit breaker passes through the zero-sequence current transformer, and the secondary side of coil connects with the electromagnetic tripper. Under normal condition, the vector sum of each phase of current passing through zero-sequence current transformer is zero. The flux of the zero-sequence current transformer is zero. And the secondary output voltage is zero and the circuit breaker doesn`t zreo, and the zero-sequence current transformer would produce the magnetic flux, and the secondary side of coil would output the voltage. Once the leak current increases to drive the output voltage at the secondary side to grow to certain level, the electromagnetic release would activate to drive the operation mechanism to act to break the contact that connects the power, finally to realize the leak protection.


House Circuit BreakersHouse Circuit BreakersHouse Circuit BreakersHouse Circuit Breakers


Product Categories : Miniature Circuit Breaker > KNB1-63 Miniature Circuit Breaker

Product Images
  • Residual Current Circuit Breaker For Building
  • Residual Current Circuit Breaker For Building
  • Residual Current Circuit Breaker For Building
  • Residual Current Circuit Breaker For Building
  • Residual Current Circuit Breaker For Building
Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters

Mobile Website Index. Sitemap


Subscribe To Our Newsletter:
Get Updates, Discounts, Special
Offers and Big Prizes!

MultiLanguage:
Copyright © 2024 Wenzhou Korlen Electric Appliances Co., Ltd. All rights reserved.
Communicate with Supplier?Supplier
Chen Ms. Chen
What can I do for you?
Contact Supplier