Company Details
  • Wenzhou Korlen Electric Appliances Co., Ltd.

  •  [Zhejiang,China]
  • Business Type:Distributor/Wholesaler , Manufacturer , Service , Trade Company
  • Main Markets: Africa , Americas , Asia , Caribbean , East Europe , Europe , Middle East , North Europe , Oceania , Other Markets , West Europe , Worldwide
  • Exporter:91% - 100%
  • Certs:ISO14001, ISO9001, ISO9002, CB, CE, EMC, RoHS, TUV, UL, OHSAS18001, CCC
  • Description:KNL1-100 3KA RCCB TUV,KNL1-100 3KA TUV,KNL1-100 RCCB TUV
Wenzhou Korlen Electric Appliances Co., Ltd. KNL1-100 3KA RCCB TUV,KNL1-100 3KA TUV,KNL1-100 RCCB TUV

Supply 3KA RCCB for house TUV

Share to:  
    Unit Price: USD 1 / Bag/Bags
    Payment Type: L/C,T/T,D/P,Paypal
    Min. Order: 1 Bag/Bags
  • Ms. Chen

Basic Info

Model No.KNL1-100

BrandKorlen

Additional Info

Packagingcarton

Productivity5000000PCS/Year

TransportationOcean,Land,Air

Place of OriginWenzhou; Zhejiang; China

CertificateCE,CB

HS Code8536200000

PortNingbo,ShangHai

Payment TypeL/C,T/T,D/P,Paypal

Product Description


KNL1   RCCB Residual Current Circuit Breaker is in conformity with the standard of IEC61008.The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk,thus,it's suitable to avoid the shock hazard and fire caused by earth leakage.The RCCB is mainly suitable for use in varieties of plants and enterprises,building.

Residual Current Circuit Breaker
Ac Residual Current Circuit Breaker
Miniature Residual Current Circuit Breaker
Residual Current Electrical Circuit Breaker

How to check your circuit breaker?
1.if your power goes off because your circuit breaker has tripped,look for the lever in the "off" position(A) or where the button has popped out(B).
2.Switch off lights and unplug all appliances on the faulty circuit.
3.Push the operating lever to the "on" position(A) .or push in the button on the circuit breaker(B).
4.If the circuit breaker continues to trip,call a licensed electrician.


Frame class 100A
Rated working voltage 240/415V
Rated frequency 50/60Hz
Rated working current 63,80,100A
Rated residual operating current 0.03,0.1,0.3,0.5A
Rated residual un-operating current 0.015,0.05,0.15,0.25A
Sensibility AC Type,A Type,S Type
Maximum operating time IΔn t≤0.1s , 5IΔn t≤0.04
Rated making and breaking capacity 1500A
Limiting value of un-operating current 6In
Rated limiting short-circuit current 3000A
Pole number 2,4P
Mechanical life 10000
Electric life 4000


Residual Current Circuit Breaker For HouseResidual Current Circuit Breaker For HouseResidual Current Circuit Breaker For House

Residual Current Circuit Breaker For House

Product Categories : Residual Current Circuit Breaker > KNL1-100 Residual Current Circuit Breaker

Product Images
  • Supply 3KA RCCB for house TUV
  • Supply 3KA RCCB for house TUV
  • Supply 3KA RCCB for house TUV
Email to this supplier
  • *Subject:
  • *Messages:
    Your message must be between 20-8000 characters

Mobile Website Index. Sitemap


Subscribe To Our Newsletter:
Get Updates, Discounts, Special
Offers and Big Prizes!

MultiLanguage:
Copyright © 2024 Wenzhou Korlen Electric Appliances Co., Ltd. All rights reserved.
Communicate with Supplier?Supplier
Chen Ms. Chen
What can I do for you?
Contact Supplier