Unit Price: | USD 1 / Bag/Bags |
---|---|
Payment Type: | L/C,T/T |
Min. Order: | 1 Bag/Bags |
Model No.: KNR8
Brand: Korlen
Theory: Thermal Relay
Size: Miniature
Action Principle: Electronic Type
Protective Characteristics: Other
Load: Micro Power Relay
Number Of Pole: Other
Electricity Type: Ac
Phase: Other
Usage: Lathe Relay
Type: Electric Parameter Relay
Rated Frequency: 50/60hz
Rated Working Current: 25;36;93a
Standards: Iec947-4;vde0660;gb14048.4
Rated Current: 0.1-400a
Rated Insulation Voltage: 660v
Packaging: carton
Productivity: 500000PCS/Year
Transportation: Ocean,Land,Air
Place of Origin: Wenzhou; Zhejiang; China
Certificate: CE;CB;
HS Code: 8536200000
Port: Ningbo,ShangHai
Payment Type: L/C,T/T
Structure feature
●Senies overload relay of thermal metal mode ,tripping class is 10A;
●Setting current continuous adjustable device;
●trip indicator;
●test button;
●reset button by hand operation and automatic reset button;
●have a pair of No and Nc insulation contact in electricity;
●mode of installation :install independently or can plug in the AC Contactor
KNR8 series Reed Relay overload relay is suitable for 50Hz/60Hz, rated voltage up 690~1000V,rated current 0.1~400A in main circuit of long time working. It is used to protect AC three-phase asynchronous motor against overload and open phase.
This products Thermal Relay conformity with IEC947-4, VDE0660,GB14048.4 standards . Reed Relay
Thermal Relay
Latching Relay
Reed Relay
Polarized Relay
Working condifion
●The altituelde should be not higher than 2000m;
●The ambient temperature:-25℃~55℃;
●The relative humidity: when +25℃,the relative humidity of air should be not more than 90%.
Feature
●Senies overload relay of thermal metal mode, tripping class is 10A;
●Setting current continuous adjustable device;
●Trip indicator;
●Test button;
●Reset button by hand operation and automatic reset button;
●Have a pair of No and Nc insulation contact in electricity;
●Mode of installation: install independently or can plug in the AC contator.
Thermal Relay
Latching Relay
Reed Relay
Polarized Relay
Parameters & Technical date
Type | Sphere of | Fuse specification (A) | |
|
| IEC947-4 | |
|
| [1" | [2" |
KNR8-50 | 0.1-0.16 | 35 | 0.5 |
| 0.16-0.25 |
| 1 |
| 1.25-0.4 |
| 1.6 |
| 0.4-0.63 |
| 2 |
| 0.63-1 |
| 4 |
| 0.8-1.25 |
| 4 |
| 1-1.6 |
| 6 |
| 1.25-2 |
| 6 |
| 1.6-2.5 |
| 6 |
| 2-3.2 |
| 10 |
| 2.5-4 |
| 10 |
| 3.2-5 |
| 20 |
| 4-6.3 |
| 16 |
| 5-8 |
| 16 |
| 6.3-10 |
| 25 |
| 8-12.5 |
| 25 |
| 10-14.5 |
| 25 |
KNR8-52 | 0.1-0.16 | 63 | 0.5 |
| 0.16-0.25 |
| 1 |
| 0.25-0.4 |
| 1.6 |
| 0.4-0.63 |
| 2 |
| 0.63-1 |
| 4 |
| 0.8-1.25 |
| 4 |
| 1-1.6 |
| 6 |
| 1.25-2 |
| 6 |
| 1.6-2.5 |
| 6 |
| 2-3.2 |
| 10 |
| 2.5-4 |
| 10 |
| 3.2-5 |
| 16 |
| 4-6.3 |
| 16 |
| 5-8 |
| 20 |
| 6.3-10 |
| 25 |
| 8-12.5 |
| 25 |
| 10-16 |
| 35 |
| 12.5-20 |
| 35 |
| 16-25 |
| 50 |
KNR8-55 | 1-1.6 | 100 | 6 |
| 1.25-2 |
| 6 |
| 1.6-2.5 |
| 6 |
| 2-3.2 |
| 10 |
| 2.5-4 |
| 10 |
| 3.2-5 |
| 16 |
| 4-6.3 |
| 16 |
| 5-8 |
| 20 |
| 6.3-10 |
| 25 |
| 8-12.5 |
| 25 |
| 10-16 |
| 35 |
| 12.5-20 |
| 50 |
| 16-25 |
| 50 |
| 20-32 |
| 80 |
| 25-36 |
| 80 |
| 32-40 |
| 80 |
| 36-45 |
| 80 |
Type | Sphere of | Fuse specification (A) | |
|
| IEC947-4 | |
|
| [1" | [2" |
KNR8-58 | 12.5-20 | 160 | 50 |
| 16-25 |
| 50 |
| 20-32 |
| 63 |
| 25-40 |
| 80 |
| 32-50 |
| 100 |
| 40-57 |
| 100 |
| 50-63 |
| 100 |
| 57-70 |
| 125 |
| 63-80 | 250 | 160 |
| 70-88 |
| 160 |
KNR8-60 | 55-80 | 250 | 160 |
| 63-90 |
| 160 |
| 80-110 | 315 | 200 |
| 90-120 |
| 224 |
| 110-135 |
| 224 |
KNR8-61 | 55-80 | 250 | 160 |
| 63-90 |
| 160 |
| 80-110 | 315 | 200 |
| 90-120 |
| 224 |
| 110-135 |
| 224 |
| 120-150 |
| 224 |
KNR8-59 | 0.1-0.16 | 25 | 0.5 |
| 0.16-0.25 |
| 1 |
| 0.25-0.4 |
| 1.6 |
| 0.4-0.63 |
| 2 |
| 0.63-1 |
| 4 |
| 0.8-1.25 |
| 4 |
| 1-1.6 |
| 6 |
| 1.25-2 |
| 6 |
| 1.6-2.5 |
| 6 |
| 2-3.2 |
| 10 |
| 2.5-4 |
| 10 |
| 3.2-5 |
| 16 |
| 4-6.3 |
| 16 |
| 5-8 |
| 16 |
| 6.3-10 |
| 16 |
| 8-12.5 | 35 | 25 |
| 10-16 | 63 | 35 |
| 12.5-20 | 63 | 50 |
| 16-25 | 63 | 50 |
| 20-32 | 80 | 63 |
| 25-40 | 125 | 80 |
| 32-40 | 160 | 100 |
| 40-57 | 160 | 125 |
| 50-63 | 160 | 125 |
KNR8-62 | 55-80 | 250 | 160 |
| 63-90 |
| 160 |
| 80-110 | 250 | 200 |
| 90-120 | 315 | 224 |
| 135-160 | 355 |
|
KNR8-66 | 80-125 | 500 | 250 |
| 125-200 |
| 315 |
| 160-250 |
| 400 |
| 200-320 |
| 400 |
| 250-400 | 800 | 500 |
The company has well experienced workforce, ranging from senior engineers and technicians to factory workers which constitutes a total population of 1,500 workers. The company covers an area of more than 50 acres of land. Construction site is more than 38000 square meters of the modern industrial zone. Korlen is equipped with modern sophisticated laboratory with high standard examination equipment. Due to our strict compliance in accordance with every country`s electric coding system, the company has managed to obtain more than 20 national patents including other accredited international certificates. This makes Korlen a standout in producing electrical protective devices among its competitors.
Product Categories : Thermal Relay
Subscribe To Our Newsletter:
Get Updates, Discounts, Special